Comet Labs 48-Port 10 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Netzwerk-Switches Comet Labs 48-Port 10 herunter. Comet Labs 48-Port 10 User manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - EX 5/7/11 RT Systems

www.mgeops.comEX 5/7/11 RT SystemsInstallation and User Manual

Seite 2

EX 5/7/11 RT Systemsc vi 86-86000-00 B01 IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS. This manual contains important instructionsthat should

Seite 3

Installation and User Manualc vii86-86000-00 B01 Safety of PersonsCAUTION: Safety of persons◗The system has its own power source (the battery). Conseq

Seite 4

EX 5/7/11 RT Systemsc viii 86-86000-00 B01 CAUTION: Record all serial numbers!CAUTION: Record All Serial Numbers!RECORD ALL SERIAL NUMBERS FOR EX 5/7/

Seite 5 - Contents

Installation and User ManualSymbol Usage c ix86-86000-00 B01Symbol UsageThis manual uses the following icon symbols with text to convey important info

Seite 6 - Section 3 Operation

(This page left blank intentionally)EX 5/7/11 RT Systemsc x86-86000-00 B01

Seite 7 - Contents c iii86-86000-00 B01

IntroductionThank you for selecting an MGE Office Protection Systems product to protect your electrical equipment.The product you selected is a part o

Seite 8

Table 1-2: Optional Accessories (See Section 1.5 for description)Part Number Description86001 Rail Kit for Power Module EX 5/7/11 RT86002 Rail Kit for

Seite 9 - Figures (continued)

Installation and User Manual1.1 System Electrical Characteristics Table 1-3: UPS Characteristics System Ratings.Table 1-4: Transformer Module Charac

Seite 10 - IMPORTANT SAFETY INSTRUCTIONS

Table 1-5: Battery Module Ratings.1.2 Standard ConfigurationThe EX 5/7/11 RT systems can be set up in tower or rack configurations.1.2.1 Tower Configu

Seite 11 - CAUTION: Safety of persons

Installation and User Manual1.2.2 Rack ConfigurationFigure 1-2: Rack Configuration with Power Module, Battery Module, and optional Transformer Module

Seite 13 - Symbol Usage

1.3 Rear Panel Components1.3.1 Power Module EX 5/7/11 RTFigure 1-3: Rear panel of the Power Module.1.3.2 Battery Module EXB 5/7/11RT With Remote Emer

Seite 14

Installation and User Manual1.3.3 EX RT Transformer Module Figure 1-5: Rear Panel of the optional Transformer Module. (PN 86211/86311)1.4 Power Modul

Seite 15 - Introduction

1.5 Optional AccessoriesOptional Accessories describes the options available for upgrades and enhancement of the EX 5/7/11 RT systems.Detailed install

Seite 16

Installation and User Manual1 — 986-86000-00 B01EX 5/7/11 RT Systems1.5.3 Multiple Battery Module Back-up Time at Full LoadStandard EX 5/7/11 RT syste

Seite 17

EX 5/7/11 RT Systems1 — 10 86-86000-00 B01 1.5.5 Battery Integration Kit with Casters(Part number 86005) Battery Integration Kit is a cart, designed t

Seite 18 - TRANSFORMER MODULE

Installation and User Manual1 — 1186-86000-00 B01EX 5/7/11 RT Systems1.5.7 Transformer Module - For use with EX 5/7/11 RT Power ModuleThis module prov

Seite 19

EX 5/7/11 RT Systems1 — 12 86-86000-00 B01 1.5.8 CLA Charger ModuleExtended back-up time (up to 8 hours at full load) requires a high power battery ca

Seite 20

Setup and Installation2.0 ScopeSetup and Installation guides the user through tools and equipment required for connecting the EX 5/7/11 RT, andbattery

Seite 21

EX 5/7/11 RT Systems2 — 2 86-86000-00 B01 2.2 Contents of Standard EX 5/7/11 RT SystemsIMPORTANT Packaging must be destroyed according to waste manage

Seite 22

Installation and User ManualFigure 2-2: Contents of EXB 5/7/11RT Battery Module.E X B R T39 40 42414344(not to scale)- EXB 5RT Battery Module Part

Seite 23

Installation and User Manualiii86-86000-00 B01EX 5/7/11 RT SystemsInstallation and User ManualRevision HistoryEX 5/7/11 RT Systems Installation and Us

Seite 24

2.3 Installation in Tower ConfigurationFollow the numerical sequence to assemble tower stands and tower stand expanders, shown in Figure 2-3.Figure 2-

Seite 25 - Quick Start

Installation and User Manual2.4 Installation in Rack Mounting Configuration2.4.1 Adjustment of Front Panel Logo and Control Panel for Rack Orientation

Seite 26

2.4.2 Prepare Battery Module for Rack Mounting IMPORTANT This step requires two people.The Battery Module is very heavy (151 lbs.). To ease its rack m

Seite 27 - Setup and Installation

Installation and User Manual2.4.3 Power, Battery, Transformer, and CLA Charger Module Rack MountingThe following steps apply to all modules. For simpl

Seite 28 - (see 1.5.1)

NOTE: This step is unique to the Power Module. It involves the installation of the I/O BoxBracket System.The I/O Box bracket system keeps the I/O Box

Seite 29 - (not to scale)

Installation and User Manual2.5 Communication PortsEX 5/7/11 RT Power Module provides 3 communication method's that can be used simultaneously:◗

Seite 30 - Power Module

2.5.2 Connecting the Dry (Relay) Contact Communication PortThe system status is indicated by the connection of common pin (Pin 5) to the appropriate p

Seite 31

Installation and User ManualA wide range of optional cards will allow your UPS to talk to nearly all equipment management systems, makingintegration f

Seite 32

2.6 Remote Emergency Power Off (REPO) Communication Port The end user is responsible for the installation of a Remote Emergency Power Off function. In

Seite 33

Installation and User Manual2.7 System ConnectionsWARNING This type of connections must be carried out by qualified electrical personnel.Before carryi

Seite 34

(This page left blank intentionally)EX 5/7/11 RT Systemsiv86-86000-00 B01

Seite 35

Proceed as follows:1. For normal AC input, make connections to L1, L2, and terminals only. No connections are required forBypass AC input. Make

Seite 36

2.7.2 Connecting EX RT Transformer Module Part number 86211/86311This module is to provide isolated 120/208/240 VAC outputs to the protected loads.Fig

Seite 37

2.7.3 Connections with Separate Normal and Bypass AC Sources (2 Mains)CAUTION: This connection requires isolation Transformer Module. Please visit our

Seite 38

Installation and User Manual2.7.4 System Connections as Frequency Converter (without Bypass AC source)Figure 2-15: Accessing Terminal Blocks for Inpu

Seite 39

2.8 Connection of Battery Module EXB1. Check that the battery circuit breaker (5) is OFF (“0”) position.2. Connect the battery power cable to the co

Seite 40 - Power Module I/O Box

Installation and User Manual2.9 Connection of Optional CLA Module1. Connect the battery power cable and battery detection cable (provided with the C

Seite 41

(This page left blank intentionally)EX 5/7/11 RT Systems2 — 2086-86000-00 B01

Seite 42

Operation3.0 ScopeOperation describes EX 5/7/11 RT systems characteristics of indicators and controls, modes and specifications andtheory of operating

Seite 43

3.2 UPS PersonalizationWARNING Before changing items from Tables, 3-1, 3-2, 3-3, and 3-4, the UPS system must be turned OFF.IMPORTANT If specific set

Seite 44

Installation and User ManualTable 3-1: Local Settings.Display Factory setting OptionsLanguage English French, Spanish, German, ItalianDate/time forma

Seite 45 - AC INPUT

ContentsContentsc i86-86000-00 B01section description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pageRevisi

Seite 46

Table 3-3: ON/OFF Features.Display Factory setting Options CommentsCold start Disabled Enabled Start on battery.Forced reboot Enabled Disabled UPS re

Seite 47 - Operation

Installation and User Manual3.3 Information Technology IT Network and Industrial Operating ModesTable 3-5: System Operation in IT Netowrk and Industr

Seite 48 - EXIT ENT

3.3.1 UPS personalization through external softwareInsert the Solution-Pac 2 CD ROM in your CD drive.◗ At the first Navigator Screen, select "Ins

Seite 49

Installation and User Manual3.4 Operating Modes3.4.1 Normal (Double Conversion) ModeFigure 3-4: Normal (Double Conversion) Mode.OFF ONOFF ON1515 16LO

Seite 50

3.4.2 ECO ModeFigure 3-5: ECO Mode Display.EX 5/7/11 RT SystemsOperation3 — 8 86-86000-00 B01 The main advantage of the ECO mode is that itreduces th

Seite 51

Installation and User Manual3.5 Operation on Battery PowerFigure 3-6: Transfer, Threshold and End of back-up time.Operation 3 — 986-86000-00 B013.5.1

Seite 52

3.6 Return of Normal AC sourceAfter an outage, the UPS restarts automatically when AC power is restored (unless this function has been disabledvia UPS

Seite 53

Maintenance4.0 ScopeMaintenance includes a troubleshooting guide of symptoms and possible solutions, hot swapping the Power Moduleand Battery Module,

Seite 54

Table 4-2: Troubleshooting Requiring MGE Office Protection Systems After-Sales Support.Symptoms Indication CorrectionLED and are on, Internal fau

Seite 55

Installation and User Manual4.2 Hot Swapping the Power ModuleThis operation can be performed without interrupting the load.Figure 4-1: Disconnecting

Seite 56

EX 5/7/11 RT SystemsContentsc ii 86-86000-00 B01 section description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 57 - Maintenance

4.3 Re-Connecting the Power ModuleThis operation can be performed without interrupting the load.Figure 4-2: Reconnect the Power Module.EX 5/7/11 RT S

Seite 58

Installation and User Manual4.4 Hot Swapping the Battery ModuleDuring the replacement of the Battery Module, it is imperative to use the same type and

Seite 59

(This page left blank intentionally)EX 5/7/11 RT Systems4 — 686-86000-00 B01

Seite 60

Appendix5.0 Electrical SpecificationsElectrical and Mechanical specifications for the EX 5/7/11 RT.5.1 System Input/Output Power RatingsTable 5-1: EX

Seite 61 - Battery Module Power Module

EX 5/7/11 RT Systems5 — 2 86-86000-00 B01 5.3 System Back-Up CharacteristicsTable 5-2: Back-Up Time (In Minutes).11kVA With 9Ah Battery Modules: 10% 2

Seite 62

Installation and User ManualTable 5-3: Battery Recharge Time to Recover 90% of the Rated Back-Up Time After Discharge at Full Load.Configuration for

Seite 63 - Appendix

Table 5-7: Efficiency on ECO Mode (All Kinds of Load) and Batteries Fully Charged.5.6 Heat RejectionTable 5-8: Full Load Heat Rejection in BTUs/hr.S

Seite 64

Installation and User Manual86-86000-00 B01MGE Office Protection Systems Customer Care CenterTechnical Support and Product ServicesTechnical questions

Seite 66

GlossaryTerm used Definition/Meaning@ At./ And/or.+/- Plus or Minus.≤ Equal to or less than.# Number.°C Degree Celsius.°F Degree Fahrenheit.Ø Phase an

Seite 67 - Customer Care Center

Installation and User Manualsection description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .pageSection 4 Ma

Seite 68

dBrnC Decibel above reference noise.DC or dc Direct current, or voltage.Earth ground A ground circuit that has contact with the earth.Electrician Refe

Seite 69 - Glossary

Glossary G — 386-86000-00 B01OSHA Occupational Safety and Health Agency.PCA Printed circuit assembly.PCB Printed circuit board.PN Part number.PWM Puls

Seite 70

EX 5/7/11 RT SystemsG — 486-86000-00 B01(This page left blank intentionally)

Seite 71

Reorder Form113 Whatney, Suite #101Irvine, CA 92618Use this form to report any errors, omissions, or other problems you have experienced, or toorder a

Seite 74

13 Whatney, Suite #101, Irvine, California 92618 • www.mgeops.comwww.mgeops.comContact MGE OfficeProtection SystemsUnited StatesMGE Office Protection

Seite 75

Figuresfigure description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page1-1: Tower Configurati

Seite 76 - Protection Systems

Installation and User ManualFigures (continued)figure description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Kommentare zu diesen Handbüchern

Keine Kommentare